Nonlinear Deformer Attributes
            Select one of the following
               options.
            
            - Low Bound
- 
                  Specifies the extent of the sine wave
                        along the deformer’s local negative Y axis. Values can be negative
                        numbers or zero. Use the slider to select values from negative 10.000
                        to 0.000. Default is ‑1.000.
                      
- High Bound
- 
                  Specifies the extent of the sine wave
                        along the deformer’s local positive Y axis. Values can be positive
                        numbers only (minimum value is 0.000). Use the slider to select
                        values from 0.000 to 10.000. Default is 1.000.
                      
- Amplitude
- 
                  Specifies the amplitude (maximum wave amount)
                        of the sine wave. Use the slider to select values from ‑5.000 to
                        5.000. Default is 0.000 (no wave).
                      
- Wavelength
- 
                  Specifies the frequency of the sine wave along the
                        deformer’s local Y axis. For greater frequency decrease the wavelength,
                        and for lesser frequency increase the wavelength. Use the slider
                        to select values from 0.100 to 10.000. Default is 2.000.
                      
- Offset
- 
                  Specifies the location of the sine wave relative
                        to the center of the deformer handle. Changing this value can create
                        a wriggling effect. Use the slider to select values from -10.000
                        to 10.000. Default is 0.000.
                      
- Dropoff
- 
                  Specifies how the amplitude decays. Negative values
                        specify a decay towards the center of the deformer handle (minimum
                        is -1.000), and positive values specify a decay away from the center
                        of the deformer handle (maximum is 1.000). Use the slider to select
                        values from -1.000 to 1.000. Default is 0.000 (no decay).