This
icon lets you create and change deviation combs.
To create deviation combs
- Pick all the scan lines/section data
sets (curves)/polygonal data sets and surfaces between which you
want to calculate the deviation.
- Click the Show deviations tool
at the bottom of the Modeling control panel.
- Adjust the options in the Deviation section
of the Modeling control panel.
To quickly display the
deviation comb
- Pick either the surface or the scan-line/section
data (curve)/polygonal data which contains the deviation comb.
- Click the Deviation button
in the Display area of the Control panel.
To quickly hide the deviation
comb
- Pick either the surface or the scan-line/section
data (curve)/polygonal data which contains the deviation comb.
- Click the Deviation button in
the Display area of the Control panel.
To delete deviation combs
- Click the Pick > Locator tool,
and then click on the deviation comb. This will highlight the deviation
comb.
- Select Delete > Delete Active to
delete this active locator.
To create minimum and maximum
deviation locators between a surface and a mesh
- Pick a mesh and surface between which
you want to calculate the minimum and maximum deviation.
- Click the Show deviations tool
at the bottom of the Modeling control panel.
- Turn the Min. and Max. options
on or off in the Deviation section of the Modeling control panel.