In the following circumstances, Smoke checks
whether or not your incoming sync matches the project timing you
are working on:
- When you load a project on start-up.
- When you change projects in the Preferences
menu.
- When you change preview timing in the
Preferences menu.
- When you change your VTR to one with
a different timing, or change the timing on your VTR.
If your video sync is
correct, you can proceed as expected.
If it does not match,
you are prompted to fix the sync and click Confirm. One of the following
occurs:
- If you click Confirm without fixing the
sync, the check is done again and you are not allowed to proceed.
- If you click outside of the Confirm button,
you proceed in “free-run” mode, and using the
workstation’s internal sync. You can work in this mode, but input
and output can have unpredictable results. No more sync checks are
done.
- If you fix the sync and click Confirm,
the workstation is now genlocked. You can proceed as expected.
The incoming video sync
is displayed in the preferences menu. See
Timing Preferences.
When changing project
timing, Smoke selects an appropriate VTR for you. The VTR devices
available depend on the VTR keyword lines uncommented in the software
initialisation configuration file. If multiple VTR matches are found
in the list, Smoke selects the first match. If no match is
found, VTR selection reverts to "No VTR selected" with the appropriate
timing.
You can also manually
select a VTR, as described in
Selecting a VTR Device For Input and
Selecting a VTR Device For Output.
NoteIf you are outputting
a clip whose timing differs from the preview timing setting in the
Preferences menu, the timing and VTR switch are done automatically
by Smoke as soon as you select the clip to open the Output
Clip menu.