Managing Field Dominance
Managing Field Dominance
Reversing Field Dominance
Changing the Scan Mode of a Project
The project
scan mode dictates how interlaced video formats are captured from tape,
sent to the broadcast monitor in-session, and output to tape. The project
scan mode also determines field-based processing.
You can change the scan mode of your project
by selecting an alternative scan mode option. Do this, for example,
to view a PAL clip in an NTSC project properly before reversing
its field dominance. Generally, changing the scan mode of a project
is a temporary measure performed only to allow for the monitoring
of clips whose format does not match the scan mode of the current
project.
To
change the scan mode of a project:
- In
the Project Management section of the Preferences menu, click the
project Edit button.
- From
the Scan Mode box, select Field 1 or Field 2.
- Confirm
that Modify Project is selected in the Project Edit box, click Apply
Changes, and then Confirm.
NoteThe effects of switching the scan mode of
a project between field 1 and field 2 are only visible on an interlaced
broadcast monitor (which accounts for the slight flicker when you
pause on an interlaced video frame). The graphics monitor displays
both fields at the same time.