Checks all, visible, or picked objects for common problems that could prevent data transfer.
Choose one of the construction presets from the drop down list. The list contains all the default and site based Construction Presets available from Preferences > Construction Options. The checks will be done using the tolerances from the preset you choose, rather than what is currently selected in the Construction Options window.
To use whatever set of tolerances is already selected in the Construction Options window (indicated by an arrow), choose Use Current Tolerances.
Check for rational geometry.
Check for periodic (closed) objects.
Check for multi-knots (multiple edit points at the same point in space that may create a sharp corner in a curve or surface).
Product Data Quality Recommended Checks
Off – No check is done for duplicate or embedded geometry.
Copies – Checks for curves or surfaces that are exact duplicates of each other. Copies have the same CVs, same knots, and same degree. If Report is set to All, the original object is marked “Original” in the Copies column of the report window.
Duplicates Within Tolerance – Checks for curves and surfaces that are duplicates of, or embedded into other curves and surfaces, within the tolerance given in the Duplicate Tolerance field.
Check for objects with a degree higher than the number specified in the text field.
Check for surfaces whose normal direction is inconsistent with the normal direction of adjacent surfaces.
The Topology Distance tolerance (in Preferences > Construction Options) must be larger than the Maximum Gap Distance for this check to find inconsistent normals.
Report objects that exceed a user-defined tolerance for positional continuity between adjacent curves or surfaces.
The tolerance value is given by Maximum Gap Distance in the Tolerances Continuity section of Preferences > Construction Options.
The Topology Distance tolerance (in Preferences > Construction Options) must be larger than the Maximum Gap Distance for this check to find gaps.
See Maximum Gap Distance.
Report objects that exceed a user-defined tolerance for tangent continuity between adjacent curves or surfaces.
The tolerance value is given by Continuity Angle in the Tolerances Continuity section of Preferences > Construction Options.
The Topology Distance tolerance (in Preferences > Construction Options) must be larger than the Maximum Gap Distance for this check to find tangent discontinuities.
See Continuity Angle.
Report objects that exceed a user-defined tolerance for curvature continuity between adjacent curves or surfaces.
The curvature deviation is calculated as:
The tolerance value is given by Continuity Curvature in the Tolerances Continuity section of Preferences > Construction Options.
The Topology Distance tolerance (in Preferences > Construction Options) must be larger than the Maximum Gap Distance for this check to find curvature discontinuities.
See Continuity Curvature.
Maximum curvature deviation allowed between objects for them to be included in the G2 continuity test.
G0, G1, G2, and Normal Consistency checks are only performed if the maximum distance between the objects is less than the Topology Distance found in Preferences > Construction Options.