Autodesk Vault 2015
Service Pack 2 for Autodesk Vault Basic 2015, Autodesk Vault
Workgroup 2015, Autodesk Vault
Professional 2015
August, 2015
Release Notes -
Readme file
Autodesk,
Inc.
In
a continuing effort to provide high quality products, Autodesk has
released
Autodesk Vault 2015 Service Pack 2 (Client) and Autodesk Vault 2015
Service
Pack 2 (Server) for Autodesk Vault Basic 2015, Autodesk Vault Workgroup
2015, and Autodesk Vault Professional 2015. The Service Pack
fixes or addresses a variety of issues pertaining to those releases.
This Service Pack 2 also contains all the previously released Hotfixes.
This
README file highlights how to download the Service
Pack, how to install the Service
Pack and what has been fixed.
NOTE:
Throughout this Readme document references to Vault 2015 will apply to
Autodesk
Vault Basic 2015, Autodesk Vault Workgroup 2015 and Autodesk Vault
Professional 2015.
DOWNLOAD LOCATION
Locate the Autodesk
Vault 2015 Service Pack 2 file at: Autodesk
Vault Services & Support
INSTALLATION
- All clients and servers should be upgraded at the same time
to the Autodesk Vault 2015 Service Pack 2
- All future Autodesk Vault 2015 hotfixes will depend on this
Service Pack being installed
- Depending
on how your UAC is configured on Windows 7 or later operating
systems, users may need to turn off User Access Control (UAC) to
install the Service Pack
- To install the Service Packs, Administrative privileges are
required.
- Thin Client Service Pack 2 installation is part of Server
Service Pack 2 installation.
- The same username which was used to install Thin Client
2015 should be used for installing Service Pack 2.
- Ensure the latest service packs of CAD applications are
installed before applying this Service pack.
- The service pack install may take
longer than expected in Windows 7 or in Windows Server 2008 R2. To
avoid that install the following Microsoft Hotfix:
http://support.microsoft.com/kb/2663352/en-us
For other Operating systems ensure Windows Update is up to date.
WARNING:
Failure to follow these instructions properly may result in unusable
sites. This procedure applies to Single Site, Multi Site
and Connected Workgroup deployments.
NOTE:
Always ensure that a successful backup has been performed before
applying this Service Pack.
Client
Service Pack 2 Installation - applicable to every
Autodesk Vault Client 2015
- Run "Autodesk Vault 2015 Service Pack 2 (Client).msp" on
the Vault Explorer client to install the Service Pack.
Server
Service Pack 2 Installation - applied to every Autodesk
Data Management Server (ADMS)
- Open the ADMS Console.
- Make sure all databases are fully migrated to the latest
version.
- Migrate all unmigrated databases and libraries before
proceeding.
- It may be necessary to detach an unmigrated database if
the Service Pack addresses a migration problem.
- Close the ADMS Console application.
- Restart the web service by typing 'iisreset' at the command
prompt.
- Run “Autodesk Vault 2015 Service Pack 2 (Server).msp” on
the ADMS server to install the Service Pack.
- DO NOT OPEN ADMS or AVFS – DATABASE MIGRATION SHOULD BE
POSTPONED
UNTIL INSTRUCTED BELOW.
- Repeat the preceding steps for every ADMS server.
- DO NOT OPEN ADMS or AVFS – DATABASE MIGRATION SHOULD BE
POSTPONED UNTIL INSTRUCTED BELOW.
Database
Update - applied ONCE from one Autodesk Data Management
Server (ADMS) instance as specified.
WARNING: DO NOT
PROCEED until Service Pack 2 has been successfully applied
on ALL ADMS and AVFS servers.
- Use the appropriate server and ADMS Console application.
- Single Site, use your only ADMS Console.
- Multi-Site (file replication), use any of the ADMS
consoles.
- Connected Workgroup (file and SQL replication) use one of
the ADMS Consoles on the Publisher Workgroup.
- Restart the web service by typing 'iisreset' at the command
prompt.
- Open the ADMS Console and perform the database migration.
- If necessary, attach any previously detached databases and
allow the migration to complete.
NOTE: On
Connected Workgroup environments, the SQL snapshot agent may not handle
generating the initial snapshot. If this occurs, restart the SQL
snapshot agent.
SUMMARY
OF ISSUES ADDRESSED
ADMS - Server:
- Files released on one workgroup would not show released on
other workgroups for a time period ranging from hours to days.
- In a replicated environment, Index Block Attributes were
not shown in ADMS Console for all workgroups due to time zone
differences.
- Resolved conflicts in replication to improve replication
performance.
- Log files have been updated to support Token Flex Licensing.
- Exporting a Vault configuration, when Category rules for
file and item exists with the same name, would result in a message
containing, "An error occurred when applying configuration".
- This update solves a problem connecting to a SSL configured
Autodesk Data Management Server when using Autodesk Vault File Server.
- System Property mappings will no longer be re-added after a
migration (B2B or full migration).
- When a Vault server is configured for SSL, users were able
to log in with the thin client but not with the SDK (Vault clients).
Client:
- Changing revision on a file could result in a "Warning:
Possible unexpected results" message.
- Performing an update in Vault Explorer immediately after
checking in a file could result in missing data in the details pane.
- CER (Crash Error Reports) resolved:
- Resolved an intermittent CER occurring when there are too
many shortcuts defined in the My Shortcuts pane.
- Some batch plot configurations with many sheets would
generate a CER.
- Additional enhancements to avoid more general CERs.
Item/BOM:
- Corrections for the Item BOM revision drop down (missing
revisions) and mismatching revisions displayed on the revision drop
down, details pane and vertical property pane.
- In an Item BOM, removing and re-adding the On/Off column
could result in application error when attempting to sort by the column.
- Enhancements to avoid some BOM export issues.
- 'Go To Item' and 'Assign/Update Item' would not work for
Items assigned to an AutoCAD Electrical DWGs.
- Selecting 'Go To Item' would sometimes result in the
message, "Sequence contains no matching element".
- When turning off BOM rows for sub-assemblies in an Item,
Parts were still visible in the Parts Only view.
- In certain circumstances, while it is possible to go to an
Item from a file, the Item cannot be found in an Item search or may not
be listed in the Items details pane.
NOTE: Once this update is applied, the affected Item must
be edited and saved to completely resolve this issue.
- In some cases, BOM data is not preserved properly resulting
in an “Unknown Server Error” during check in or result in an Item
update failure.
- The Vault Configuration Administrator is now able to set
the File Item link Behavior to always create a standard component link
for each sub-component created using the Assign/Update Item command.
- Administrator may run the utility and set the option to
always create standard component links for NEW sub-component during the Assign/Update item process.
- As a result of this configuration change, Assign/Update
Item command will set all NEW sub-component links to be standard
component links. The resulting link behavior will be the same as
standard component link. Assign/Update Item will NOT update existing
sub-component links.
- All NEW sub-component links will NOT honor the
auto-select first duplicates flag.
- Vault Configuration Administrators may enable this
configuration change by running a utility (via command line, no User
Interface) and passing the proper arguments such as Vault Server Name,
Vault name, Administrator ID (sa), etc. There will be no end-user
level
configuration setting to allow individual users to overwrite the
Administrative setting (e.g. this is a Global Vault environment
setting).
- To enable this configuration change:
- Download the configuration change utility provided with this
Service Pack
- Unzip the configuration change files into a Vault Server
local drive
- Browse to the 'SetCreateStdComponentLinkSwitch' folder
to find the 'fix.bat' script
- Open the 'fix.bat' configuration script to configure
the parameters according to your Vault environment
- Execute the 'fix.bat' configuration script to set the
designated server flag
- To undo this change, repeat the above steps using the
'RemoveCreateStdComponentLinksSwitch' files provided with this Service
Pack
- In replicated Vault environments, run the configuration
change script on the Publisher only. Running it on Subscribers may
cause conflicts.
Copy Design:
- Certain characters in a path (ex. apostrophe or ampersand)
would cause Copy Design to fail with the message, "Illegal characters
in path".
AutoCAD:
- Some ACAD files would have an unresolved reference after
performing move/rename in Vault.
- Additional improvement for opening an AutoCAD Civil 3D
sheet set containing a large number of sheets.
- Using Dynamic Blocks in an AutoCAD DWG would result in
property extraction for only one block. Other blocks would not be
available for property mapping.
Inventor:
- Logging into Vault from Inventor as a "Content Center
library read only user" would result in an object reference error
message.
- CER (Crash Error Reports) resolved:
- Deleting then reattaching a part with an attachment would
result in a CER in Inventor when expanding the part in the Vault pane.
- Inventor Vault pane workflows related to attachment
deletion.
- Enhancements to avoid CERs for certain operations like
deleting a reference or a group of references, suppressing references
and switching amongst LODs.
- Enhancements to avoid CERs for some Vault add-in startup
crashes.
Thin Client:
- Correction for being unable to download the current
Released file when the tip revision is NOT in a Released state.
- Performing an advanced search in the Thin Client would not
allow paging for large search result sets. Some horizontal scrolling
may be required to activate paging in some cases.
- Preview of visualization files was not working for Thin
Client when using Internet Explorer 10.
Revit:
- When more than one user works on a Revit project, files and
the global project were not maintained properly in the Vault.
SYSTEM REQUIREMENTS
Client:
- Autodesk AutoCAD Mechanical 2015 Service Pack 1
- "DWGs with Xrefs" check in will fail without 'Autodesk
AutoCAD Mechanical 2015 Service Pack 1' installed.
- Autodesk AutoCAD Civil 3D 2015 Service Pack 2
- The AutoCAD Civil 3D sheet set improvement requires the
installation of 'AutoCAD Civil 3D 2015 Service Pack 2'.
LEGAL
NOTICE
Autodesk Vault Professional, Autodesk Vault
Workgroup, Autodesk Vault Basic, Autodesk Data
Management Server, Autodesk Vault File Server, Autodesk Inventor,
AutoCAD, AutoCAD Mechanical, and
AutoCAD Electrical are trademarks of Autodesk, Inc. in the United
States and/or other countries. Windows
Server 2008, Windows Server 2008 R2, Windows Server 2012, Microsoft SQL
Server 2008, Microsoft SQL Server 2008 R2, Microsoft SQL Server 2012,
Windows 7, Windows 8, Windows 8.1, Microsoft Office 2010
and Microsoft Office 2013 are either trademarks or registered
trademarks of Microsoft Corporation in the United States and/or other
countries. All other trademarks are the property of their respective
owners.
Return to
Top
Copyright © 2015 Autodesk, Inc.