MEDIASTUDIO 4.3.2 QUALIFICATION
MediaStudio is the generic name for both the Explore & Advanced Visualizer lines. The versions numbers had been synchronised until now, but as 3Design 4.3.3 had been delivered with PowerAnimator/Studio 8.2, the Explore release was finally called 4.3.3, instead of 4.3.2 and is compatible with PowerAnimator/Studio 8.2.
| Products | CD Version | CD Date | Notes | ||||||||||||||
|
EXPLORE PROFESSIONAL
|
4.3.3 | Oct/97 | Composer/Vizpaint on separate CD | ||||||||||||||
|
ADVANCED VISUALIZER
|
4.3.2 | Oct/97 | Composer/Vizpaint on separate CD |
MediaStudio 4.3.2 will load and run under IRIX 5.3 and many systems (Indy, Indigo2 Extreme) are problem-free in this configuration. However, should you encounter an OS or graphics related problem, the Assist Hotline will only be able to recommend that you "upgrade to IRIX 6.2 including any indicated patches." Assist will still be able to answer questions about the functionality of the package.
Whether you choose to run MediaStudio 4.3.2 under IRIX 5.3 or
IRIX 6.2 (or higher), it is crucial that operating system patches
be applied in order to rectify known problems that will seriously
impede the usability and/or stability of MediaStudio 4.3.2. Please
see the Qualification Chart for exact details.
Customers with valid SGI software support should have already
received IRIX 6.2, which was sent out starting in May 1996. Customers
in North America who have not received IRIX 6.2 yet, should call
the Technical Assistance Center at 1-800-800-4744. International
customers should call their local SGI office.
Qualification for this release was performed using recommended patch sets from SGI. It is strongly recommended that any indicated patches be installed for the proper operation of the MediaStudio 4.3.2 software.
Patch sets are patches that Silicon Graphics recommends you install
on your system. These patches are considered crucial for successful
system operation. Patch sets are updated every month and new patches
are regularly added and replaced as required. It is possible for
new workstations to have a newer patch set installed than what
is listed here. In such a case it is not recommended that you
remove that patch set and downgrade to what is listed here. It
is unlikely that the new patchset will cause any problems but
in the event that a patch related problem occurs you may have
to contact SGI support at the above listed number.
Customers with valid SGI software support can gain access to patches through the worldwide web:
Customers without worldwide web access should call the Technical
Assistance Center or their local SGI office as indicated above.
You can subscribe to an e-mail notification service for patch
sets. This service will give you a detailed account of patch set
modifications and additions. Subscription is located in the Supportfolio
Online Membership section.
| MediaStudio 4.3.2 Qualification Chart | |||
|---|---|---|---|
| Hardware | Qualified on IRIX... |
|
Will run on IRIX... |
| Octane Any Configuration | 6.4 for Origin, Onyx2 and Octane [7] | July 1st + patch1953 | |
| Onyx2 Any Configuration | 6.4 for Origin, Onyx2 and Octane[8] | July 1st | |
| Origin 200, 2000 | 6.4 for Origin, Onyx2 and Octane[8] | July 1st | |
| O2 Any Configuration | 6.3 for the O2 including R10000 [6] | July 1st | |
| Indigo2 R10000 Impact Graphics | 6.2 all impact [1] | July 1st | |
| Indigo2 R10000 Extreme | Untested: 6.2[1] | July 1st | |
| Indigo2 R4400 Impact Graphics | 6.2 all impact[1] | July 1st | 5.3 all impact [2][4] |
| Power Indigo2 R8000 | Not Supported | ||
| Indigo2 R4000, R4400, R4600 XL, XZ, Extreme | 6.2 [1] | July 1st | 5.3 [3][4] |
| Indy R4000, R4400, R4600, R5000 with 24bit graphics | 6.2 [1] | July 1st | 5.3 [3][4] |
| Indigo R4000 with 24 bit graphics | 6.2 [1] | July 1st | 5.3 [3][4] |
| Crimson RealityEngine | Untested: 6.2 | ||
| Crimson Elan | Untested: 6.2 | ||
| Onyx R4400, VTX, RealityEngine2 | 6.2 [5][9] | July 1st + patch2038 | |
| Onyx R10000, VTX, RealityEngine2 | Untested: 6.2 [5][9] | July 1st | |
| Onyx R4400 InfiniteReality | 6.2 [9] | July 1st | |
| Onyx R10000 InfiniteReality | 6.2 [9] | July 1st | |
| Power Onyx R8000 | Not supported | ||
| Challenge R4400 | 6.2 [9] | July 1st | 5.3 [4] |
| Power Challenge R8000 | Not Supported | ||
| Power Challenge R10000 | 6.2 [9] | July 1st | |
Platforms marked Untested have not been tested in any way by Alias, and at time of press are NOT Qualified.
Hardware Notes
For any product other than Render Software, all SGIs require a
z-buffer, except Indy XL, and Indigo2 XL. Eight-bit graphics configurations
are not supported.
| TIP: When installing patchsets use the i A command (in Software Manager select Panes->Command from the menu) to select all applicable patches. | |
| [1] | All noted IRIX 6.2 machines should have the July 1 patch set installed which includes: 1227, 1270, 1397, 1417, 1422, 1447, 1472, 1480, 1482, 1485, 1492, 1499, 1510, 1598, 1607, 1613, 1615, 1639, 1666, 1678, 1703, 1717, 1723, 1745, 1746, 1753, 1768, 1825, 1861, 1893, 1918, 1961, 1973, 1982, 2042, 2044, 2255. |
| [2] | In addition to IRIX 5.3 All Impact, patches 1271 & 1332 should also be installed. |
| [3] | For all Non-Impact Graphics, IRIX 5.3 machines, patch 1402 should be installed. |
| [4] | All IRIX 5.3 machines should have patches 342, 983 & 998. In the case the patch 1095 is installed on an R5000 machine, it has to be deinstalled. |
| [5] | IRIX 6.2 systems with RealityEngine2 graphics require patch 2038. This should be installed instead of patch 1808 which are incompatible with each other. |
| [6] | In addition to IRIX6.3 O2 R10000, the July 1 patch set should be installed which includes: 1725, 1759, 1773, 1778, 1795, 1818, 1819, 1836, 1876, 1881, 1894, 1955, 1974 2008, 2044, 2077, 2090. The qualified OS can be identified in the following way: uname -R displays "6.3 O2 R10000" |
| [7] | In addition to IRIX6.4 S2MP+OCTANE, the July 1 patch set should be installed which includes: 1724, 1765, 1820, 1827, 1847, 1853, 1856, 1868, 1894, 1902, 1908, 1945, 1956, 1968, 1975, 1984, 2001, 2006, 2007, 2035, 2044, 2078, 2091. Once the patchset has been installed, the patch 1953 needs to be installed as well, it replaces the patch 1945, and fixes a graphical problem for 3Design on the Solid Impact graphic board. This patch can be found on the MediaStudio4.3.2 CD, under /CDROM/awdist6.4. The qualified OS can be identified in the following way: uname -R displays "6.4 S2MP+OCTANE". |
| [8] | In addition to IRIX6.4 S2MP+OCTANE, the July 1 patch set should be installed which includes: 1776, 1820, 1841, 1868, 1886, 1903, 1924, 1927, 1984, 2015, 2044, 2058, 2061, 2065, 2076, 2121, 2175. The qualified OS can be identified in the following way: uname -R displays "6.4 S2MP+OCTANE" |
| [9] | In addition to IRIX6.2, the July 1 patch set should be installed which includes: 1227, 1270, 1397, 1417, 1452, 1460, 1485, 1492, 1499, 1503, 1510, 1536, 1591, 1598, 1607, 1613, 1639, 1678, 1699, 1703, 1723, 1753, 1768, 1893, 1918, 1973, 2042, 2044, 2119, 2255. |
MediaStudio 4.3.2 IS NOT QUALIFIED for R2000 and R3000 based systems:
In addition, the following Graphics Systems ARE NOT QUALIFIED:
Last Updated: Friday, 07-Nov-97 17:26:20